Romanian Journal of Ecology & Environmental Chemistry
RJEEC Magazine Logo

Correlation between odour and hydrogen sulphide concentrations from municipal wastewater treatment plant immissions


Authors: GEORGETA-OLGUTA POPA, CRISTIAN CONSTANTIN, SIMONA MARIANA CALINESCU, VALENTIN STANCU, GHEORGHITA TANASE, LAURA NOVAC

Keywords: hydrogen sulphide, odour concentration, wastewater treatment plant.
https://doi.org/10.21698/rjeec.2023.210

The study focused on odours generated by hydrogen sulphide (H2S) immissions from a municipal wastewater treatment plant in a city of 2 million people. Odour awareness was vital to monitor environmental pollution and human’s safety. H2S was released from decomposition of organic matter, sulphites (SO32-) and sulphates (SO42-) by anaerobic microorganisms used in the biological stage of wastewater treatment. H2S was responsible for odours coming from the treatment plant. Long exposure (8 hours) to 2-5 ppm causes headaches and watery eyes, and 50 ppm irritates the airways. Maximum permissible concentrations for H2S are 0.006 ppm (24 hours) and 0.011 ppm (30 minutes). In Romania there are no limits on the concentration of odours. The sludge pumping station from the wastewater treatment plant registered the highest odour concentration at 36.000 OUE/m3, with significant levels of H2S primarily found there. Nevertheless, the activated sludge aeration system effectively eliminated around 99% of the H2S through degradation and absorption processes. The correlation between H2S and odour has been proved by a direct proportional relationship with a ratio of 25.000. Experimental determinations and mathematical modelling, using the Aermod View program, contributed to a deeper understanding of the impact of odours on the environment and on sensitive receptors, showed maximum odour concentrations of 38.8 ouE/m3 at the site of the municipal wastewater treatment plant and 5 ÷7 ouE/m3 at receptors, but without affecting residential areas.